Frequently Asked Questions

How can you add extra parameters to order files via template (EPSON, Primera)
Last Updated 9 years ago

Perennity DICOM submits job order files to EPSON and Primera autoloaders. These orders contain a number of default parameters. It is possible to add some extra parameters by editing a template that can be found here (if it doesn't exist you can create it):

C:\Program Files (x86)\Perennity\Module AutoLoader\templates

The template are called EPSON.txt or PRIMERA.txt. You may change the parameter values, but make sure to leave the rest of the file intact to avoid potential problems.
Example template contents for EPSON:

[CD]
Writing_Speed =
Close_Disc = YES
Format = UDF102

[DVD]
Writing_Speed =
Close_Disc = YES
Format = UDF102

[DVD DL]
Writing_Speed =
Format = UDF102


Please check the EPSON TD Bridge Reference Guide for permitted values.

In Media Burner v6, the templates are stored here: C:\ProgramData\PerennityV6\Configuration

Please Wait!